600W pure sine wave mppt inverter DC 10.5-30 or 20-50 to AC 110V/220Vgrid inversorpower inverter wo


US $84.24Original Price : US $108.00 (22%)  

Discount Offer 600W pure sine wave mppt inverter DC 10.5-30 or 20-50 to AC 110V/220Vgrid inversorpower inverter wo with FREE Shipping Worldwide!


 4.75



Product description

[32915319015]

600W pure sine wave inverter DC10.5-30 or 20-50 to AC 110V/220V,grid inversor,power inverter work with Solar Battery panel







Please note---inverter is designed for solar panels







Input 10.5-30VDCwhich can be suitable for 18V (36 cells pv panel).







If customers want to use this inverter for battery, please connect 24V battery for this inverter.







Input 20-50VDCwhich can be suitable for 24V / 30V 36V (48/60/72 cells pv panel).







If customers want to use this inverter for battery, please connect 36V battery for this inverter.











Product Introduction



Grid tie solar inverter is a compact unit, which directly converts direct current into alternating current for powering appliances and/or office equipments and connecting to utility grid. The AC output from this inverter is synchronized and in-phase with the utility grid. It is a key device of power generation systems such as PV power generation system, wind turbine power generation system. Grid tie solar inverter specially optimized design to work with modularization of DC power supplies which includes the mainstream solar modules, 18V (36 cells), 30V (60 cells) and 36V (72 cells) monocrystal and/or Polycrystalline solar panels, wind turbines and batteries. Grid tie inverter is stabilization, reliable and high conversion efficiency items. It is the best choice for PV power generation systems.



This grid tie inverter can be easily placed and attached to the rack underneath of PV module. No need spaces for independent installation and low voltage DC wire connects from the PV module to inverter can eliminate the risk of high DC voltage. Distributed modularization design philosophy for inverter insures the productiveness of the whole system and will not affect by a single point of failure. Each grid tie inverter is individually connected to each PV module in the array. This unique configuration means that an individual Maximum Peak Power Point Tracker (MPPT) controls each PV modules and insures that the maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array which may be affected by shading, soiling, orientation or mismatch, etc. Inverter insures top performance for maximizing energy production from the whole PV system and gets return on investment in less time.







MainAdvantages Features



1.Unique circuit design, choice of import industrial electronic components, higher efficiency, more stable performance.







2.Creative MPPT technology, efficiency more than 99%, faster reaction, more sensitive of reaction and more reliable of Maximum power point locking.







3.Parallel modular design, small volume, distributed installation, easy for system configuration, flexible for combination, strong expansibility of system.







4.Adopting high-frequency isolation transformer type, high efficiency, high security.







5.Perfect electrical protection function.







6.Aluminum alloy housing, not rust, heat-resisting and cold-resistant as well as anti-corrosion.







7.Getting electronic circuit design, appearance design and other core technology patents.















Technical Parameters Table
Power













600W








800W
Solar panels













620W








820W
DC MAX input













660W








860W
The Voltage of Matched solar panel













Vmp: 18-21V, Voc: 20-24V








Vmp: 26-39V, Voc: 34-45V








Vmp: 18-21V, Voc: 20-24V








Vmp: 26-39V, Voc: 34-45V
DC input range













10.5-30V








20-50V








10.5-30V








20-50V
MPPT Voltage













15-23VDC








24-36VDC








15-23VDC








24-36VDC
DC MAX current













50A








40A








65A








50A
AC MAX output













640W








840W
AC output range













120VAC(90-140VAC) or 230VAC(170-260VAC)
Frequency range













50Hz/60Hz
Power Factor













>97.5%
THD













<5%
Phase Shift













<1%
Peak Efficiency/110V













82%








87%








82%








87%
Stable Efficiency /110V













79%








84%








79%








84%
Peak Efficiency/220V













82%








87%








82%








87%
Stable Efficiency/220V













80%








85%








80%








85%
Protection













Islanding; Short-circuit; converse connection; Low Voltage; Over Voltage; Over temperature Protection
Work Temperature













‘-25°C-80°C
Work Humidity













0%~90%RH non-condensing
Grade of Waterproof













Indoor design
Show













1 Red and 1 Green
Cooling













Fan
Stand-by Power













2-3W
EMC













EN61000-6-3:2007 EN61000-6-1:2007
Grid Disturbance













EN 50178+EN 62109-1+VDE0126-1-12
Grid Detection













DIN VDE 1026 UL1741
Certificate













CE FCC RoHS
Net Weigtht













1.7kgs/pc








2.5kgs/pc
Gross Weight













2.6kgs/pc








3.1kgs/pc
Size (LxWxH)













22x16.5x5.3cm
Carton (LxWxH)













31x21x12cm

Real Product Show























Inverter Diagram







I. Single Inverter connection







A. Inverter work with solar panels.







This inverter has two DC voltage range. They are 10.5-30VDC and 20-50VDC.







10.5-30VDC range is for 36cells-Vmp:18-21V:Voc:20-24V solar panels. For example1000W, if you have 8pcs 150W 18V (36cells) solar panel, you can make 8pcs solar panel in series. And then connect the PV array output to the inverter DC side.







20-50VDC range is for 60cells-Vmp:26-30V:Voc:34-38V or 72cells-Vmp:35-39V:Voc:42-46V. This range can suitable for two version solar panels. For example1000W , if you have 5pcs 250W 30V (60 cells) solar panel, you can make 5pcs in series to connect the inverter. Or you have 4pcs 300W 36Vv(72 cells) solar panel, you also can make them in series to connect the inverter.















B. Inverter work with battery.







If you want to use this grid tie inverter for battery, then please use 24VDC battery with 10.8-30VDC inverter. 36VDC battery with 20-45VDC inverter.







Because this inverter is designed for solar panels which with MPPT function. So we don't very suggest customers to use it for battery. It may short the inverter service life.











C. Grid tie inverter works in the wind solar hybrid system.







Few wind turbine is 36V output. So in the wind power system, you only can choose 10.8-30VDC inverter. The battery voltage is 24V in the system,







P.S. This grid tie inverter can't connect to wind turbine directly. In the wind power system, it must connect a battery and then use battery connect to inverter.











II. Inverter Stack Wiring







A. Plug several inverters to the grid socket directly.







B. Single Phase Connection











C. Three Phase Connection









Status Indications of LED

1. Red LED indicator lights up under any conditions include but not limited:

a)Low-voltage protection (DC input voltage lower than Min. input voltage of inverters);

b)Over-voltage protection (DC input voltage higher than Max. input voltage of inverters)'

c)Over-temperature protection (inverters will shut down for power output when temperature of body of inverters higher than 75-80, and inverter will be automatically restart up when temperature down to 40-50);

d)Power grid fault protection when 120VAC or 230VAC grid power outage and/or tripped;

e)Islanding protection: inverter will be automatically shut down for power output when disconnect with power grid.

2. Green LED indicator lights up under any conditions include but not limited:

a)Green LED flash: adjusting for power output, MPPT operating for tracking;

b)Green LED long light: indicates inverter locking-in Max. output power operation status.

3. Please note that above operations only run at grid-connected statu

Design Standards


1. Chinese "safe standard GF 004" "grid standard GF004" "electromagnetic compatibility standards GB/T 17626";

2. American "safety standard UL 1741" "grid standard IEEE 1547" "Electromagnetic Compatibility FCC Pt.15";
?
3. German "safety standard EN 62109-1/-2" "grid standard VDE 4105" "EMC standards EN 61000-6-X".s.